40–61 kW, two fans
2384 × 1094 × 2240 mm (L × D × H), one compressor and an R290 charge of 4.5 or 4.9 kg.
Seven reversible air source heat pumps for heating, cooling and hot water, with up to 75 °C flow. Cascade them for larger buildings, and let our design team specify the plant around your project.
Two casings: two fans for 40–61 kW, three fans for 70 and 84 kW.
Inverter scroll compressors, EC fans and an inverter pump modulate from 30 to 100% of output. The 75 °C flow suits retrofit schemes that keep existing high-temperature emitters, subject to design.
SCOP at 35 °C, AEROTOP EVO P 70 (EN 14825, average climate)
ErP heating class at 35 °C on the 40, 47, 70 and 84
maximum flow temperature
minimum outdoor air in heating

2384 × 1094 × 2240 mm (L × D × H), one compressor and an R290 charge of 4.5 or 4.9 kg.

3402 × 1094 × 2240 mm (L × D × H), two compressors and an R290 charge of 10 kg.
All models run on a 400 V three-phase supply. Select a model for its product page and documents.
Swipe sideways to see every column.
| Model | A7/W35 | A7/W55 | SCOP 35 / 55 °C | ErP 35 / 55 °C | R290 | L × D × H | Operating weight |
|---|---|---|---|---|---|---|---|
| AEROTOP EVO P 40 | 40.1 kW, COP 3.92 | 37.0 kW, COP 2.71 | 4.51 / 3.54 | A+++ / A++ | 4.9 kg | 2384 × 1094 × 2240 mm | 714 kg |
| AEROTOP EVO P 47 | 46.8 kW, COP 3.71 | 42.9 kW, COP 2.57 | 4.45 / 3.51 | A+++ / A++ | 4.9 kg | 2384 × 1094 × 2240 mm | 714 kg |
| AEROTOP EVO P 50 | 50.4 kW, COP 3.81 | 47.4 kW, COP 2.67 | 4.36 / 3.51 | A++ / A++ | 4.5 kg | 2384 × 1094 × 2240 mm | 760 kg |
| AEROTOP EVO P 56 | 55.8 kW, COP 3.78 | 51.2 kW, COP 2.60 | 4.29 / 3.47 | A++ / A++ | 4.5 kg | 2384 × 1094 × 2240 mm | 760 kg |
| AEROTOP EVO P 61 | 61.0 kW, COP 3.73 | 55.7 kW, COP 2.55 | 4.22 / 3.41 | A++ / A++ | 4.5 kg | 2384 × 1094 × 2240 mm | 760 kg |
| AEROTOP EVO P 70 | 70.2 kW, COP 3.91 | 65.9 kW, COP 2.74 | 4.70 / 3.63 | A+++ / A++ | 10 kg | 3402 × 1094 × 2240 mm | 1021 kg |
| AEROTOP EVO P 84 | 84.4 kW, COP 3.74 | 76.6 kW, COP 2.56 | 4.54 / 3.60 | A+++ / A++ | 10 kg | 3402 × 1094 × 2240 mm | 1021 kg |
Heating output and COP to EN 14511:2022 with air at 7 °C and water at 30/35 °C or 50/55 °C, in the standard acoustic mode. SCOP to EN 14825:2022 for the average climate. Source: Elco AEROTOP EVO P planner manual (September 2026) and UK data sheet (November 2026).
Standard, Silenced and Super-Silenced, set per unit on site. Silenced lowers sound power by 2 to 4 dB(A) and Super-Silenced by 6 to 10 dB(A), at a reduced maximum output.
Modbus RTU over RS-485 as standard, SG Ready and demand-limit inputs, and set-point control by 0–10 V or 4–20 mA.
Heat output, power input, live COP or EER and cumulative MWh on the unit display and over Modbus.
A built-in inverter pump, flow switch and 6 bar safety valve, with 2" Victaulic connections. The water strainer and automatic deaerator are supplied with the unit.
The refrigerant compartment is separated from the electrical panel, with two leak sensors and an ATEX extraction fan.
Heating and hot water from -20 to 42 °C outdoor air, with a heated condensate pan and anti-freeze heaters on the plate exchanger.
Every model also produces chilled water, with outdoor air up to 48 °C. It can manage a boiler or electric heater as an auxiliary heat source.
The units share a local network, and sizes can be mixed in one cascade. In a cascade, the BMS connects to the master unit.
Two 4" manifolds and two butterfly valves to isolate each unit, for up to six units on one water branch.
With the hydraulic kit fitted, units stand 165 mm apart, so a cascade takes less plant space.
Ask the team to add them to your quote.
Swipe sideways to see every column.
| Code | Accessory | Use |
|---|---|---|
| 4270489 | Finned coil protection grill 40–61 kW | Protects the coil from contact with objects or people. |
| 4270491 | Finned coil protection grill 70–84 kW | Protects the coil where people pass, such as car parks and terraces. |
| 4270488 | Anti-vibration mount support | Rubber mounts under the base frame reduce vibration passed to the structure. |
| 4270490 | Cascade piping hydraulic kit | Manifolds and isolating valves for cascades, with a 165 mm side gap. |
| 4270487 | Closing caps for cascade hydraulic kit | Caps the open ends of the cascade manifolds. |
Elco's UK specifications for all seven models.
Download the data sheet (PDF)Elco's B2B brochure for the range, with the cascade and acoustic options.
Download the brochure (PDF)Each product page also carries the UK ErP label and product fiche for that model. Installation and planner manuals, wiring diagrams and the Modbus protocol are sent with confirmed orders.
Send the heat-loss and cooling loads. We can propose the model or cascade, and the hydraulic and control strategy for your specification.
Get a quote for the units and accessories, with design support for the plant and commissioning.
Our team can design, supply, install and commission the system as one package.
Tell us about the building and the loads, and we will come back with a design and quote.