Skip to Content
For consultants, installers and developers

Elco AEROTOP EVO P: 40–84 kW commercial heat pumps on R290.

Seven reversible air source heat pumps for heating, cooling and hot water, with up to 75 °C flow. Cascade them for larger buildings, and let our design team specify the plant around your project.

40–84 kW seven models Up to 75 °C flow Heating to -20 °C outdoor air Up to 16 units in cascade
Elco AEROTOP EVO P outdoor units side by side: the two-fan 40 to 61 kW casing and the three-fan 70 to 84 kW casing

Two casings: two fans for 40–61 kW, three fans for 70 and 84 kW.

Natural refrigerant, commercial scale

One range for heating, cooling and hot water.

Inverter scroll compressors, EC fans and an inverter pump modulate from 30 to 100% of output. The 75 °C flow suits retrofit schemes that keep existing high-temperature emitters, subject to design.

4.70

SCOP at 35 °C, AEROTOP EVO P 70 (EN 14825, average climate)

A+++

ErP heating class at 35 °C on the 40, 47, 70 and 84

75 °C

maximum flow temperature

-20 °C

minimum outdoor air in heating

Two casings

Seven outputs in two footprints.

Elco AEROTOP EVO P two-fan casing for the 40 to 61 kW models, seen from the front corner
AEROTOP EVO P 40, 47, 50, 56 and 61

40–61 kW, two fans

2384 × 1094 × 2240 mm (L × D × H), one compressor and an R290 charge of 4.5 or 4.9 kg.

Elco AEROTOP EVO P three-fan casing for the 70 and 84 kW models, seen from the front corner
AEROTOP EVO P 70 and 84

70–84 kW, three fans

3402 × 1094 × 2240 mm (L × D × H), two compressors and an R290 charge of 10 kg.

The range

AEROTOP EVO P at a glance.

All models run on a 400 V three-phase supply. Select a model for its product page and documents.

Swipe sideways to see every column.

Elco AEROTOP EVO P R290 models with heating output and COP at A7/W35 and A7/W55, seasonal efficiency, ErP class, refrigerant charge, dimensions and operating weight
Model A7/W35 A7/W55 SCOP 35 / 55 °C ErP 35 / 55 °C R290 L × D × H Operating weight
AEROTOP EVO P 4040.1 kW, COP 3.9237.0 kW, COP 2.714.51 / 3.54A+++ / A++4.9 kg2384 × 1094 × 2240 mm714 kg
AEROTOP EVO P 4746.8 kW, COP 3.7142.9 kW, COP 2.574.45 / 3.51A+++ / A++4.9 kg2384 × 1094 × 2240 mm714 kg
AEROTOP EVO P 5050.4 kW, COP 3.8147.4 kW, COP 2.674.36 / 3.51A++ / A++4.5 kg2384 × 1094 × 2240 mm760 kg
AEROTOP EVO P 5655.8 kW, COP 3.7851.2 kW, COP 2.604.29 / 3.47A++ / A++4.5 kg2384 × 1094 × 2240 mm760 kg
AEROTOP EVO P 6161.0 kW, COP 3.7355.7 kW, COP 2.554.22 / 3.41A++ / A++4.5 kg2384 × 1094 × 2240 mm760 kg
AEROTOP EVO P 7070.2 kW, COP 3.9165.9 kW, COP 2.744.70 / 3.63A+++ / A++10 kg3402 × 1094 × 2240 mm1021 kg
AEROTOP EVO P 8484.4 kW, COP 3.7476.6 kW, COP 2.564.54 / 3.60A+++ / A++10 kg3402 × 1094 × 2240 mm1021 kg

Heating output and COP to EN 14511:2022 with air at 7 °C and water at 30/35 °C or 50/55 °C, in the standard acoustic mode. SCOP to EN 14825:2022 for the average climate. Source: Elco AEROTOP EVO P planner manual (September 2026) and UK data sheet (November 2026).

Elco AEROTOP EVO P with the compressor compartment open, showing the scroll compressor and copper refrigerant pipework below the V-shaped coil
Key features

Built for plant rooms, rooftops and BMS-run buildings.

  • Three acoustic modes

    Standard, Silenced and Super-Silenced, set per unit on site. Silenced lowers sound power by 2 to 4 dB(A) and Super-Silenced by 6 to 10 dB(A), at a reduced maximum output.

  • BMS and smart-grid ready

    Modbus RTU over RS-485 as standard, SG Ready and demand-limit inputs, and set-point control by 0–10 V or 4–20 mA.

  • Integrated energy meter

    Heat output, power input, live COP or EER and cumulative MWh on the unit display and over Modbus.

  • Hydraulics on board

    A built-in inverter pump, flow switch and 6 bar safety valve, with 2" Victaulic connections. The water strainer and automatic deaerator are supplied with the unit.

  • R290 safety built in

    The refrigerant compartment is separated from the electrical panel, with two leak sensors and an ATEX extraction fan.

  • Heating down to -20 °C

    Heating and hot water from -20 to 42 °C outdoor air, with a heated condensate pan and anti-freeze heaters on the plate exchanger.

  • Reversible cooling

    Every model also produces chilled water, with outdoor air up to 48 °C. It can manage a boiler or electric heater as an auxiliary heat source.

Cascade

Scale up without a separate controller.

  • Up to 16 units under one master

    The units share a local network, and sizes can be mixed in one cascade. In a cascade, the BMS connects to the master unit.

  • Modular hydraulic kit

    Two 4" manifolds and two butterfly valves to isolate each unit, for up to six units on one water branch.

  • 165 mm side gap

    With the hydraulic kit fitted, units stand 165 mm apart, so a cascade takes less plant space.

Two Elco AEROTOP EVO P units installed side by side on a concrete base beside a modern commercial building
Accessories

Accessories, supplied separately.

Ask the team to add them to your quote.

Swipe sideways to see every column.

Elco AEROTOP EVO P accessories by product code
Code Accessory Use
4270489Finned coil protection grill 40–61 kWProtects the coil from contact with objects or people.
4270491Finned coil protection grill 70–84 kWProtects the coil where people pass, such as car parks and terraces.
4270488Anti-vibration mount supportRubber mounts under the base frame reduce vibration passed to the structure.
4270490Cascade piping hydraulic kitManifolds and isolating valves for cascades, with a 165 mm side gap.
4270487Closing caps for cascade hydraulic kitCaps the open ends of the cascade manifolds.
Documents

Data sheet and brochure.

AEROTOP EVO P data sheet

Elco's UK specifications for all seven models.

Download the data sheet (PDF)

AEROTOP EVO P brochure

Elco's B2B brochure for the range, with the cascade and acoustic options.

Download the brochure (PDF)

Each product page also carries the UK ErP label and product fiche for that model. Installation and planner manuals, wiring diagrams and the Modbus protocol are sent with confirmed orders.

An Elco AEROTOP EVO P unit standing against the wall of a commercial building, with planting in the foreground
Working with Thermal Earth

From specification to commissioning.

  • Consultants

    Send the heat-loss and cooling loads. We can propose the model or cascade, and the hydraulic and control strategy for your specification.

  • Installers

    Get a quote for the units and accessories, with design support for the plant and commissioning.

  • Developers

    Our team can design, supply, install and commission the system as one package.

Common questions

AEROTOP EVO P questions

It depends on the design heat load, the flow temperature and how much redundancy the building needs. Send us the loads and we can size a single unit or a cascade.

The units are sealed and charged at the factory, so no refrigerant work is needed on site. Siting must follow the R290 safety clearances in Elco's installation manual. We check them as part of the design.

They are sent with confirmed orders. The data sheet and brochure are on this page, and each product page has the UK ErP label and product fiche.

Planning a commercial heat pump project?

Tell us about the building and the loads, and we will come back with a design and quote.